The power factor at which a paralleled AC generator operates is usually adjusted by the ().
A

connected load

B

prime mover speed

C

field excitation

D

generators rated voltage


参考答案

参考解析
解析: 暂无解析
更多 “单选题The power factor at which a paralleled AC generator operates is usually adjusted by the ().A connected loadB prime mover speedC field excitationD generators rated voltage” 相关考题
考题 When voltage and current developed in an AC circuit reach their peak values at the same time, the power factor is _____.A.laggingB.leadingC.maximumD.minimum

考题 The power factor of an AC generator operating singularly is determined by the_______ .A.connected loadB.prime mover speedC.field excitationD.generator's rated voltage

考题 A technician suspects the AC voltage into a PC power supply is bad. Which of the following toolswould MOST likely be used to confirm the diagnosis?() A. MultimeterB. OscilloscopeC. Cable testerD. Power supply tester

考题 Equal power factors on paralleled AC generators are maintained by an automatic ________.A.governor control switchB.reverse power relayC.reverse current relayD.voltage regulator

考题 材料:The field current supply in older machines comes from a lower voltage direct current generator or exciter on the same shaft as the alternator. Modern machines however are either statically excited or of the high-speed brush-less type. The exciter is required to operate to counter the effects of power factor for a given load. The power factor is a measure of the phase difference between voltage and current and is expressed as the cosine of the phase angle. With a purely resistance load the voltage and the current are in phase, giving a power factor of one. The power consumed is therefore the product of voltage and current. Inductive or capacitive loads, combined with resistance loads, produce lagging or leading power factors which have a value less than one.The power consumed is therefore the product of current, voltage and power factor. The alternating current generator supplying a load has a voltage drop resulting from the load. When the load has a lagging power factor this voltage drop is considerable. Therefore the exciter, in maintaining the alternator voltage, must vary with load current and also the power factor. The speed change of the prime mover must also be taken into account.问题: The word “machines” in the passage refers to _____.A.the direct current generatorB.the alternating current generatorC.the exciterD.the prime moverWhich of the following statements is true according to the passage ?A.With a purely resistance load, the power factor is zeroB.Inductive loads combined with resistance loads produces leading power factorsC.Capacitive loads combined with resistance loads produces lagging power factorsD.With a purely resistance load, the phase angle is zeroWhen the load has a lagging power factor this voltage drop is considerable. This sentence means that _____.A.with a purely resistance load, the voltage drops too muchB.there is a considerable voltage drop in the capacitive load combined with resistance loadC.when the load is the capacitive load combined with resistance load, the voltage drops to zeroD.when the load is the inductive load combined with resistance load, the voltage drop is fairly largeThe exciter must vary with: ① load current ② the power factor, ③ speed change of the prime mover.A.①B.②C.①②D.①②③请帮忙给出每个问题的正确答案和分析,谢谢!

考题 英译汉:power factor

考题 Failure of which of the following parts could cause the laptop display to stop functioning?() (Select TWO).A、Power inverterB、AC adapterC、Multicard readerD、BacklightE、Keyboard

考题 A laptop operates on battery power when connected with an AC adapter. Once the battery discharges, the computer turns off and will not turn back on. Which of the following are the MOST likely causes of the laptop issue? ()(Select TWO).A、The LCD monitor’s power inverter does not function properly.B、The operating system’s power settings prevent the battery from charging.C、The battery is not compatible with the laptop.D、The internal power connection on the motherboard is faulty.E、The power adapter is not working.

考题 Which of the following are potential sources of EMI?()A、Strong magnetsB、Toaster ovensC、Cordless phonesD、Flat panel TVsE、AC power runs

考题 A technician suspects the AC voltage into a PC power supply is bad. Which of the following toolswould MOST likely be used to confirm the diagnosis?()A、MultimeterB、OscilloscopeC、Cable testerD、Power supply tester

考题 单选题A three-phase alternator operates at 450 volts with a power factor of 0~8.If the ammeter indicates 250 amperes, what should be the KW meter reading ().A 90~0 kwB 127~27 kwC 155~70 kwD 194~85 kw

考题 单选题A DC generator is used to supply direct current in order to maintain an AC generator field and is known as a/an ()A rotorB statorC exciterD armature

考题 单选题Which of the following statements represents an advantage of an electromagnetic clutch?()A Large misalignments can be tolerated between the shaft and engine couplingB Slip is held to a minimum when reversing shaft rotationC Engine torsion vibrations to the driven shaft are eliminatedD It aids in maintaining power factor

考题 单选题The power factor of an AC generator operating singularly is determined by the ()A connected loadB prime mover speedC field excitationD generators rated voltage

考题 单选题When voltage and current developed in an AC circuit reach their peak values at the same time, the power factor is ()A laggingB leadingC maximumD minimum

考题 单选题The frequency of an AC generator is controlled by the ()A rheostatB governorC exciterD capacitor

考题 单选题A diesel driven emergency generator is prevented from being paralleled with the ships service generators by ()A an electrical interlock systemB an automatic paralleling trip switchC the synchronizing oscilloscopeD the reverse current relay

考题 单选题Most often () is attached to the engine-propeller shaft for efficient electric power generation.A a variable-speed AC generatorB a fixed-speed AC generatorC an air blowerD a DC generator

考题 单选题Equal power factors on paralleled AC generators are maintained by an automatic ().A voltage regulatorB reverse power relayC reverse current relayD governor control switch

考题 单选题Why is it desirable to operate paralleled AC generators at the same power factor?()A Circulating currents are kept to a minimumB Field excitation losses are kept to a minimumC Generator rotors will have a lesser tendency to huntD Because a power factor increase will decrease kilowatt output

考题 单选题The booster pump, which supplies diesel oil to() , should have a possibility of being powered by compressed air or by emergency power.A the main enginesB the auxiliary enginesC the emergency generator engineD the auxiliary engines and the main engine(s)

考题 单选题The alternating current generator supplying a load has a voltage drop resulted from the loadWhen the load has a lagging power factor this voltage drop ().A is smallB may be neglectedC is usefulD is considerable

考题 多选题A laptop operates on battery power when connected with an AC adapter. Once the battery discharges, the computer turns off and will not turn back on. Which of the following are the MOST likely causes of the laptop issue? ()(Select TWO).AThe LCD monitor’s power inverter does not function properly.BThe operating system’s power settings prevent the battery from charging.CThe battery is not compatible with the laptop.DThe internal power connection on the motherboard is faulty.EThe power adapter is not working.

考题 单选题A diesel generator has just been paralleled with an AC turbo-generator, but the load can not be properly divided.This could be caused by()A an incorrect diesel generator governor speed droop adjustmentB a faulty reverse power relay within the main circuit breaker assemblyC unsynchronized isochronous load distribution adjustmentsD a different speed setting on each unit

考题 单选题Which of the following types of motors is often designed for use in correcting power factor?()A PolyphaseB Wound-rotorC InductionD Synchronous

考题 单选题When paralleled, AC generators must have the same ()A frequencyB number of phasesC phase rotationD All of the above

考题 单选题A constant output voltage from an AC generator is maintained by the ().A prime mover governorB exciter generatorC voltage regulatorD reverse power relay