网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
The valve on the discharge side of a cargo pump on a tank vessel will usually be a().
A
butterfly valve
B
spectacle valve
C
check valve
D
globe valve
参考答案
参考解析
解析:
暂无解析
更多 “单选题The valve on the discharge side of a cargo pump on a tank vessel will usually be a().A butterfly valveB spectacle valveC check valveD globe valve” 相关考题
考题
To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the_______ .A.suction service valve as a vaporB.suction service valve as a liquidC.discharge service valve as a vaporD.charging valve as a liquid
考题
The valve on the discharge side of a cargo pump on a tank vessel will usually be a ______.A.butterfly valveB.spectacle valveC.check valveD.globe valve
考题
In Cargo Survey,T.C.V.refers to ______.A.total calculated volumeB.terminal cargo volumeC.tank cargo valveD.tolerance of cargo valve
考题
Which method should be used to warm up the pump turbines prior to discharge ________.A.Lock the turbine rotor and slowly bleed in steam until operating temperature is reachedB.Run the pump at high speed with the discharge valves closedC.Run the turbine at slow speed with the pump disconnectedD.Shut the discharge valve and run the pump at slow speed
考题
Before discharge of cargo tank ballast is undertaken,______.A.the deck isolating valve is openB.flue gas isolating valveC.blower suction valveD.blower discharge valve
考题
Cargo pump relief valves are piped to the ______.A.cargo pump pressure gaugesB.crossover lines interconnecting two pumpsC.suction side of pumpsD.atmosphere through pump vents
考题
The fitting at the end of a cargo line in a tank that allows suction to be taken close to the bottom of a tank is a ______.A.Suction endB.StrainerC.Bell-mouthD.Vacuum valve
考题
What is the purpose of the relief valve of a cargo pump ________.A.Provides for the removal of vaporsB.Allows two or more tanks to be filled at the same timeC.Provides for the emergency shutdown of the pumpD.Permits the return of cargo to the suction side of the pump
考题
Which statement is TRUE concerning deep well self-priming pumps ________.A.When loading oil cargo,it is always loaded via the discharge line through to the pump until the tank is topped offB.Stripping systems are generally eliminated for the purposes of cargo handlingC.In recent years deep well pumps have become increasingly unpopular in product tankers and medium size crude shipsD.There is no danger of damaging the pump from overheating
考题
You start a centrifugal cargo pump to discharge cargo.The pump works for a while and then loses suction.This could be caused by ______.A.The pump running backwardsB.Incomplete primingC.The discharge head being too highD.All of the above
考题
单选题Cargo pump relief valves are piped to the().A
cargo pump pressure gaugesB
crossover lines interconnecting two pumpsC
suction side of pumpsD
atmosphere through pump vents
考题
单选题The discharge side of every fire pump must be equipped with a().A
gate valveB
pressure gaugeC
check valveD
strainer
考题
单选题If a centrifugal bilge pump were continually operated with the discharge valve closed the ().A
motor overload would openB
relief valve would openC
pump would eventually overheatD
motor would overheat
考题
单选题What is a characteristic of all centrifugal cargo pumps? ()A
They are self-primingB
Decreasing the speed of rotation will decrease the discharge pressureC
Opening the discharge valve wider will increase the discharge pressureD
All of the above
考题
单选题Which method should be used to warm up the pump turbines prior to discharge().A
Lock the turbine rotor and slowly bleed in steam until operating temperature is reachedB
Run the pump at high speed with the discharge valves closedC
Run the turbine at slow speed with the pump disconnectedD
Shut the discharge valve and run the pump at slow speed
考题
单选题In setting the valves on a steam-smothering system on a tank vessel,the master control valve to cargo tanks should be().A
open and individual tank valves openB
open and the individual tank valves closedC
closed and the individual tank valves closedD
closed and the individual tank valves open
考题
单选题What action must be taken when an individual cargo tank is closed off from the inert gas system by the tank isolation valve?()A
The tank must be gas freedB
The tank must be ballastedC
The tank must be vented to the atmosphereD
The bypass valve must also be closed
考题
单选题A relief valve for a cargo pump is generally installed().A
after the discharge valveB
between the pump and discharge valveC
after the suction valveD
between the pump and suction valve
考题
单选题When starting a centrifugal pump, the discharge valve should be ().A
closedB
opened fullyC
cracked openD
partly open
考题
单选题The advantage of a centrifugal pump as compared with a reciprocating pump is that ().A
discharge is continuousB
it has no internal valvesC
upon accidental closing of discharge valve, excessive pressure will not build upD
all of the above are true
考题
单选题The valve on the discharge side of a cargo pump on a tanker will usually be a().A
butterfly valveB
spectacle valveC
check valveD
globe valve
考题
单选题One of the consequences in continuing to operate a centrifugal bilge pump with the discharge valve closed, is that the ().A
motor overload will openB
relief valve will openC
pump will overheatD
motor will overheat
考题
单选题The simplest method to use for determining if a centrifugal pump is operating as designed, is to ().A
closely observe the pump discharge temperatureB
close off the discharge valve, and watch for a rise in pressureC
momentarily close off the suction valve, and watch for a rise in pressureD
use a clamp on ammeter and compare the readings to past records
考题
单选题What is the purpose of a relief valve?()A
to fill 2 tanks at the same timeB
to use pump at a higher pressureC
to return liquid to suction side if discharge valve is closedD
All of the above are true
考题
单选题The relief valve is located on the()A
discharge side of condenserB
discharge side of compressorC
outlet of the evaporatorD
receiver tank
考题
单选题The combined fan discharge rate in an inert gas system is related to the().A
shoreside loading rateB
maximum cargo pump discharge rateC
boiler forced draft fan rateD
size of the largest cargo tank
考题
单选题If the relief valve on the discharge side of a hydraulic pump lifts, the cause could be ().A
a low load on the unitB
a clogged pump suction strainerC
a blockage in the line between the pump and hydraulic motorD
the hydraulic motor turning too fast
热门标签