网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
Companycom will be using Virtual IO Server to share Ethernet adapters. What can be done to prevent network failure of the client if a Virtual IO Server goes down?()
A

Create two virtual adapters on the client, each one from a separate Virtual IO Server

B

Enable dead gateway detection on the client so that the network traffic can be rerouted

C

Have a spare network card on standby in the client in case the Virtual IO Server goes down

D

Create an etherchannel adapter on the client using one Virtual Ethernet adapter from two  separate Virtual IO Servers


参考答案

参考解析
解析: 暂无解析
更多 “单选题Companycom will be using Virtual IO Server to share Ethernet adapters. What can be done to prevent network failure of the client if a Virtual IO Server goes down?()A Create two virtual adapters on the client, each one from a separate Virtual IO ServerB Enable dead gateway detection on the client so that the network traffic can be reroutedC Have a spare network card on standby in the client in case the Virtual IO Server goes downD Create an etherchannel adapter on the client using one Virtual Ethernet adapter from two separate Virtual IO Servers” 相关考题
考题 Companycom has a p5 595 with no DVD configured on this server. How can they install the Virtual IO Server code?()A、From the HMCB、From a NFS mountC、From a FTP serverD、From any CD or DVD drive on another server

考题 Companycom is installing a Virtual IO Server to reduce the number of fibre channel adapters needed for each partition. The customer wants to use disk based copy functions to replicate the data on the LUNs. How can this be accomplished?()A、Create LVM mirrors between LUNsB、MPIO is necessary as the device driverC、Use separate fibre adapters in the Virtual IO Server for each LUND、Virtual IO Server is a disk subsystem and must control the LUNs behind it

考题 Companycom will be using Virtual IO Server to share Ethernet adapters. What can be done to prevent network failure of the client if a Virtual IO Server goes down?()A、Create two virtual adapters on the client, each one from a separate Virtual IO ServerB、Enable dead gateway detection on the client so that the network traffic can be reroutedC、Have a spare network card on standby in the client in case the Virtual IO Server goes downD、Create an etherchannel adapter on the client using one Virtual Ethernet adapter from two separate Virtual IO Servers

考题 Companycom has a p5 590 that has their production LPAR, their Tivoli Storage Manager (TSM) LPAR, and several other LPARs. What method would provide connectivity between the production LPAR, and the TSM LPAR, but be isolated from the other LPARs in the system without utilizing a Virtual IO Server or physical adapter resources?()A、Use shared memory and semaphores to transfer the data to the TSM LPARB、Provide gigabit Ethernet adapters in each LPAR and run a crossover cableC、Create a Virtual Ethernet between the production server and the TSM LPARsD、Create a Virtual Ethernet between the TSM server LPAR and the non-production LPARs

考题 Companycom is migrating from a p690 to a p5 595 utilizing APV Virtual IO features. They have created their profiles for their two Virtual IO Servers. The first Virtual IO Server is installed and running. When trying to DLPAR the DVD/ROM the task fails on the HMC. What is the probable cause?()A、APV key is not registeredB、Networking and DNS are not configuredC、/etc/hosts table on HMC is not configuredD、Virtual IO Server dose not support DLPAR

考题 A system administrator has set up a Virtual IO Server to manage three micropartitioned LPARs. Physical disks are attached to the Virtual IO Server which is accessed through Multipath IO.  What should the administrator know about monitoring for error conditions with virtual disks?()A、Both permanent and temporary virtual hardware error messages are logged to each client partition sharing the device.B、Both permanent and temporary error messages for virtual hardware are logged at each occurrence on the Virtual IO Server and then propagated to the client partition.C、Temporary error messages for virtual hardware are logged at each occurrence on the Virtual IO Server. Permanent error messages for virtual hardware are stored on the client partition.D、Temporary error messages for virtual hardware will not necessarily be propagated to the client partition. Permanent error messages for virtual hardware are only logged once on the Virtual IO Server.

考题 Companycom will be using the Virtual IO Server to share both FC and Ethernet adapters among multiple LPARs. The customer is using mostly web services in the LPARs. Which of the following should be considered?()A、Shared Ethernet Adapters and Virtual SCSI services require separate Virtual IO Servers.B、Virtualized adapters require essentially the same Virtual IO Server resources regardless of adapter type.C、Shared Ethernet Adapters require significantly more Virtual IO Server resources than Virtual SCSI services.D、Virtual SCSI services require significantly more Virtual IO Server resources than Shared Ethernet Adapters.

考题 A client has the need to reboot one of their Virtual IO Servers. What command(s) would be run to list the clients that are dependant on Virtual IO Server disk and network resources?()A、lsmap -all -netB、lsclient -disk -netC、lsdev -virtual -clientD、lsmap -all; lsmap -net

考题 What type of configuration can provide the best availability in a Virtual IO Server environment?()A、Provide multiple paths to all resources through 2 or more Virtual IO ServersB、Mirror all disk resources on the Virtual IO Server to present to the client LPARC、Mirror all disk resources on the client LPAR to the shared SCSI on the Virtual IO ServerD、Trunk multiple Ethernet adapters on the Virtual IO Server to a single Shared Ethernet Adapter (SEA)

考题 Companycom has successfully established their p5 LPAR environment on a POWER5 p5 590 running AIX 5.2. They are now ready to move to Virtual IO. What would be required to do Virtual IO?()A、Apply APAR IY62262 to the current AIX 5.2 Maintenance level 04. Virtual IO Server is not required. B、Purchase Advanced POWER Virtualization software, upgrade to AIX 5.3 maintenance level 1 and apply APAR IY60349. Virtual IO Server is not required. C、Verify that there are enough resources to add a Virtual IO Server, upgrade to AIX 5.3 with APAR IY60349, create a Virtual IO Server after applying APAR IY62262. D、Verify that there are enough resources to add a Virtual IO Server, create a Virtual IO Server and apply APAR IY62262, verify that the system is at AIX 5.2 with Maintenance level 04.

考题 Companycom LPAR that is using a Virtual IO Server needs to be more highly available. How can this be accomplished using APV features?()A、Reallocate the Virtual IO Server disks to the user LPARB、Create a stripe-group within the Virtual IO Server to protect against disk failureC、Reconfigure the user LPAR to use both locally owned disk and a Virtual SCSI diskD、Create a second Virtual IO Server and reconfigure the user LPAR to mirror across both Virtual IO Servers

考题 Companycom is using shared processor LPARs exclusively, including the Virtual IO Server. The users are complaining about response time. The application LPARs can be heavy processor users. The Virtual IO Server has been measured to be processor constrained. How should the Virtual IO Server's shared processor LPAR be configured?()A、Capped and with a lower shareB、Uncapped and with a lower shareC、Uncapped and with a higher shareD、Capped and with no change in share

考题 Your network contains two Active Directory sites named Site1 and Site2. Only Site1 can be accessed from the Internet. You have an Exchange Server 2010 organization.  You deploy a Client Access server in Site1 and enable Windows Integrated Authentication for OutlookWeb App (OWA).  In Site2, you deploy a Mailbox server and a Client Access server.  You need to configure the Exchange organization to meet the following requirements: .Allow users to access their mailboxes from the Internet by using OWA  .Prevent authentication prompts from displaying when users connect to OWA by using domain- joinedcomputers that are connected to the internal network  What should you do?()A、Modify the Exchange virtual directory on the Client Access server in Site1.B、Modify the Exchange virtual directory on the Client Access server in Site2.C、Modify the OWA virtual directory on the Client Access server in Site1.D、Modify the OWA virtual directory on the Client Access server in Site2.

考题 Companycom wants to use Virtual SCSI disks to boot multiple operating systems from the same disk. How will the volumes appear in the Virtual IO Server and how will the logical volumes appear in the partition?()A、The Virtual SCSI disks are defined as logical volumes in the Virtual IO Server. The logical volumes appear as real devices (hdisks) in the client partitions. B、The Virtual IO adapters are connected to a virtual host bridge. On the Virtual IO Server they are vdisks, on the client partition, the exported disks are visible as virtual disks. C、The Virtual SCSI disks are represented in the ODM as a bus device whose parent is sysplanar0. Logical volumes will be assigned to the Virtual IO Server and virtual disks, vdisks, in the client partition. D、The Virtual IO adapters are represented as adapter devices with the virtual host bridge as their parent. On the Virtual IO Server they are vdisks attached to vscsi, on the client partition the exported disks are visible as virtual disks.

考题 单选题Companycom LPAR that is using a Virtual IO Server needs to be more highly available. How can this be accomplished using APV features?()A Reallocate the Virtual IO Server disks to the user LPARB Create a stripe-group within the Virtual IO Server to protect against disk failureC Reconfigure the user LPAR to use both locally owned disk and a Virtual SCSI diskD Create a second Virtual IO Server and reconfigure the user LPAR to mirror across both Virtual IO Servers

考题 单选题Companycom is installing a Virtual IO Server to reduce the number of fibre channel adapters needed for each partition. The customer wants to use disk based copy functions to replicate the data on the LUNs. How can this be accomplished?()A Create LVM mirrors between LUNsB MPIO is necessary as the device driverC Use separate fibre adapters in the Virtual IO Server for each LUND Virtual IO Server is a disk subsystem and must control the LUNs behind it

考题 单选题A system administrator has set up a Virtual IO Server to manage three micropartitioned LPARs. Physical disks are attached to the Virtual IO Server which is accessed through Multipath IO.  What should the administrator know about monitoring for error conditions with virtual disks?()A Both permanent and temporary virtual hardware error messages are logged to each client partition sharing the device.B Both permanent and temporary error messages for virtual hardware are logged at each occurrence on the Virtual IO Server and then propagated to the client partition.C Temporary error messages for virtual hardware are logged at each occurrence on the Virtual IO Server. Permanent error messages for virtual hardware are stored on the client partition.D Temporary error messages for virtual hardware will not necessarily be propagated to the client partition. Permanent error messages for virtual hardware are only logged once on the Virtual IO Server.

考题 单选题Companycom has successfully established their p5 LPAR environment on a POWER5 p5 590 running AIX 5.2. They are now ready to move to Virtual IO. What would be required to do Virtual IO?()A Apply APAR IY62262 to the current AIX 5.2 Maintenance level 04. Virtual IO Server is not required. B Purchase Advanced POWER Virtualization software, upgrade to AIX 5.3 maintenance level 1 and apply APAR IY60349. Virtual IO Server is not required. C Verify that there are enough resources to add a Virtual IO Server, upgrade to AIX 5.3 with APAR IY60349, create a Virtual IO Server after applying APAR IY62262. D Verify that there are enough resources to add a Virtual IO Server, create a Virtual IO Server and apply APAR IY62262, verify that the system is at AIX 5.2 with Maintenance level 04.

考题 单选题A client has the need to reboot one of their Virtual IO Servers. What command(s) would be run to list the clients that are dependant on Virtual IO Server disk and network resources?()A lsmap -all -netB lsclient -disk -netC lsdev -virtual -clientD lsmap -all; lsmap -net

考题 单选题Companycom will be using the Virtual IO Server to share both FC and Ethernet adapters among multiple LPARs. The customer is using mostly web services in the LPARs. Which of the following should be considered?()A Shared Ethernet Adapters and Virtual SCSI services require separate Virtual IO Servers.B Virtualized adapters require essentially the same Virtual IO Server resources regardless of adapter type.C Shared Ethernet Adapters require significantly more Virtual IO Server resources than Virtual SCSI services.D Virtual SCSI services require significantly more Virtual IO Server resources than Shared Ethernet Adapters.

考题 单选题Companycom is using shared processor LPARs exclusively, including the Virtual IO Server. The users are complaining about response time. The application LPARs can be heavy processor users. The Virtual IO Server has been measured to be processor constrained. How should the Virtual IO Server's shared processor LPAR be configured?()A Capped and with a lower shareB Uncapped and with a lower shareC Uncapped and with a higher shareD Capped and with no change in share

考题 单选题What type of configuration can provide the best availability in a Virtual IO Server environment?()A Provide multiple paths to all resources through 2 or more Virtual IO ServersB Mirror all disk resources on the Virtual IO Server to present to the client LPARC Mirror all disk resources on the client LPAR to the shared SCSI on the Virtual IO ServerD Trunk multiple Ethernet adapters on the Virtual IO Server to a single Shared Ethernet Adapter (SEA)

考题 单选题Your network contains two Active Directory sites named Site1 and Site2. Only Site1 can be accessed from the Internet. You have an Exchange Server 2010 organization.  You deploy a Client Access server in Site1 and enable Windows Integrated Authentication for OutlookWeb App (OWA).  In Site2, you deploy a Mailbox server and a Client Access server.  You need to configure the Exchange organization to meet the following requirements:.Allow users to access their mailboxes from the Internet by using OWA  .Prevent authentication prompts from displaying when users connect to OWA by using domain- joinedcomputers that are connected to the internal network  What should you do?()A Modify the Exchange virtual directory on the Client Access server in Site1.B Modify the Exchange virtual directory on the Client Access server in Site2.C Modify the OWA virtual directory on the Client Access server in Site1.D Modify the OWA virtual directory on the Client Access server in Site2.

考题 单选题Companycom has a p5 590 that has their production LPAR, their Tivoli Storage Manager (TSM) LPAR, and several other LPARs. What method would provide connectivity between the production LPAR, and the TSM LPAR, but be isolated from the other LPARs in the system without utilizing a Virtual IO Server or physical adapter resources?()A Use shared memory and semaphores to transfer the data to the TSM LPARB Provide gigabit Ethernet adapters in each LPAR and run a crossover cableC Create a Virtual Ethernet between the production server and the TSM LPARsD Create a Virtual Ethernet between the TSM server LPAR and the non-production LPARs

考题 单选题Your network contains two Active Directory sites named Site1 and Site2. Only Site1 can be accessed from the Internet. You have an Exchange Server 2010 organization.  You deploy a Client Access server in Site1 and enable Windows Integrated Authentication for OutlookWeb App (OWA).  In Site2, you deploy a Mailbox server and a Client Access server.  You need to configure the Exchange organization to meet the following requirements: .Allow users to access their mailboxes from the Internet by using OWA  .Prevent authentication prompts from displaying when users connect to OWA by using domain- joined computers that are connected to the internal network  What should you do?()A Modify the Exchange virtual directory on the Client Access server in Site1.B Modify the Exchange virtual directory on the Client Access server in Site2.C Modify the OWA virtual directory on the Client Access server in Site1.D Modify the OWA virtual directory on the Client Access server in Site2.

考题 单选题Companycom is migrating from a p690 to a p5 595 utilizing APV Virtual IO features. They have created their profiles for their two Virtual IO Servers. The first Virtual IO Server is installed and running. When trying to DLPAR the DVD/ROM the task fails on the HMC. What is the probable cause?()A APV key is not registeredB Networking and DNS are not configuredC /etc/hosts table on HMC is not configuredD Virtual IO Server dose not support DLPAR

考题 单选题Companycom wants to use Virtual SCSI disks to boot multiple operating systems from the same disk. How will the volumes appear in the Virtual IO Server and how will the logical volumes appear in the partition?()A The Virtual SCSI disks are defined as logical volumes in the Virtual IO Server. The logical volumes appear as real devices (hdisks) in the client partitions. B The Virtual IO adapters are connected to a virtual host bridge. On the Virtual IO Server they are vdisks, on the client partition, the exported disks are visible as virtual disks. C The Virtual SCSI disks are represented in the ODM as a bus device whose parent is sysplanar0. Logical volumes will be assigned to the Virtual IO Server and virtual disks, vdisks, in the client partition. D The Virtual IO adapters are represented as adapter devices with the virtual host bridge as their parent. On the Virtual IO Server they are vdisks attached to vscsi, on the client partition the exported disks are visible as virtual disks.