Combustible gas indicators measure the presence of combustible gas as a percentage of the____.
A.flash point
B.upper explosive limit
C.lower explosive limit
D.fire point
参考答案
更多 “ Combustible gas indicators measure the presence of combustible gas as a percentage of the____.A.flash pointB.upper explosive limitC.lower explosive limitD.fire point ” 相关考题
考题
Before entering a fuel tank that has been cleaned, it should be checked with an oxygen indicator and a/an ____.A.Orsat apparatusB.flame safety lampC.Halide torchD.combustible gas indicator
考题
An inert gas system on a tanker should be used to ______.A.prevent the generation of flammable or combustible gas in tanksB.blow out cargo lines to prevent the build up of gas concentrationsC.dilute tank atmospheres to keep gas concentrations below the lower explosive limitD.prevent fires in the pumproom by continually displacing flammable vapors
考题
What is the best instrument for establishing a safe working area before welding in a confined space?A.An oxygen indicatorB.A combustible gas indicatorC.A combination combustible gas and oxygen indicatorD.A flame safety lamp
考题
Combustible gas indicators operate by drawing an air sample into the instrument ______.A.Over an electrically heated platinum filamentB.Where it is mixed with nitrogenC.Where it is ignited by a sparking deviceD.Where its specific gravity is measured
考题
What is used to test a tank for oxygen content ________.A.Combustible gas indicatorB.Vapor indicatorC.Atmosphere analyzer kitD.None of the above
考题
You are testing a tank that contained gasoline by using a combustible gas indicator.Under testing,the tank sample caused the needle to move rapidly to 100 on the dial then fall to zero.What is the concentration of flammable gas ________.A.Less than the flammable rangeB.Within the flammable rangeC.Over the flammable rangeD.The explosimeter is defective and giving a false reading
考题
Which instrument is suitable for determining the presence of explosive concentrations of fuel oil vapors in tanks ________.A.A flame safety lampB.A combustible gas indicatorC.A liquid cargo meterD.All of the above
考题
Which statement is TRUE concerning combustible gas indicators ________.A.One sample of air is adequate to test a tankB.They do not work properly where there is a lack of oxygenC.They will detect a lack of oxygenD.They are calibrated to read the percentage chance of explosion
考题
Deficient oxygen content inside a chain locker can be detected with ______.A.litmus paperB.a combustible gas indicatorC.an oxygen breathing apparatusD.an oxygen indicator
考题
单选题What is NOT a responsibility of the tankerman in charge of loading an unmanned tank barge? ()A
Enforcement of smoking restrictionsB
Restricting vessels from coming alongside the bargeC
Insuring that a combustible gas indicator is aboardD
Protecting cargo hose with chafing gear
考题
单选题A combustible gas indicator meter is calibrated to read the percentage of().A
vapor to oxygenB
the flammable limit concentrationC
the autoignition concentrationD
the lower explosive limit concentretion
考题
单选题A combustible gas indicator is used to determine ().A
if there is sufficient oxygen to support lifeB
the toxicity of flammable gases or vaporsC
the amount ofCO2 present in flue gasD
the presence of flammable gases or vapors in the air
考题
单选题Camphor oil is classified as a().A
Grade A flammable liquidB
Grade C flammable liquidC
Grade D combustible liquidD
Grade E combustible liquid
考题
单选题A pumproom is suspected of accumulating gases after a ventilation machinery breakdown. Where should the combustible gas indicator case be placed when testing the pumproom atmosphere for combustible gases? ()A
In the lower level of the pumproomB
In the middle level of the pumproomC
In the upper level of the pumproomD
On the deck outside the pumproom
考题
单选题A pyrometer is an instrument commonly used to measure()A
cylinder pressureB
flame intensityC
exhaust gas temperatureD
crankshaft axial alignment
考题
单选题Deficient oxygen content inside a chain locker can be detected with().A
litmus paperB
a combustible gas indicatorC
an oxygen breathing apparatusD
an oxygen indicator
考题
单选题A combination combustible gas and oxygen indicator is an instrument that measures the() of both combustible gas and oxygen; each is indicated on a separate meter.A
purifiesB
combinationsC
concentrationsD
filters
考题
单选题Combustible gas indicators measure the presence of combustible gas as a percentage of the().A
flash pointB
upper explosive limitC
lower explosive limitD
fire point
考题
单选题Combustible gas indicators operate by drawing an air sample into the instrument().A
over an electrically heated platinum filamentB
where it is mixed with nitrogenC
where it is ignited by a sparking deviceD
where its specific gravity is measured
考题
单选题A diesel engine crankcase ventilation system ()A
prevents spark generationB
removes combustible gasesC
determines the level of combustible gasesD
provides inert gas generation in crankcase
考题
单选题The blower type crankcase ventilation system ()A
removes combustible gases in the crankcaseB
prevents the formation of combustible gases in the crankcaseC
cools lubricating oilD
improves cold weather starting
考题
单选题What can be used to measure the percentage of oxygen inside a chain locker?()A
Flame safety lampB
Combustible gas indicatorC
Oxygen indicatorD
H2S meter
考题
单选题SOLAS regulations require that the inert gas system shall be capable of delivering inert gas with an oxygen content of not more than what percentage?()A
5%B
8%C
6%D
3%
考题
单选题Before entering a tank,always check the vapor content()a combustible gas indicator.A
withB
byC
ofD
for
考题
单选题Each ship having an inert gas system must have a portable instruments to measure concentrations of hydrocarbon vapor in inert atmospheres and also to measure().A
nitrogenB
oxygenC
carbon dioxideD
water vapor
考题
单选题An inert gas system on a tanker should be used to().A
prevent the generation of flammable or combustible gas in tanksB
blow out cargo lines to prevent the build up of gas concentrationsC
dilute tank atmospheres to keep gas concentrations below the lower explosive limitD
prevent fires in the pumproom by continually displacing flammable vapors
考题
单选题An inert gas system on a tanker should be used to().A
prevent the generation of flammable or combustible gas in tanksB
blow out cargo lines to prevent gas concentrationsC
dilute tank atmospheres to keep gas concentrations below the lower explosive limitD
prevent fires in the pumproom by continually displacing flammable vapors