考题
Which of the following defines memory interleaving?()
A. The distribution of data written across all the memory DIMMs and the L1 cacheB. The distribution of data written across all the memory DIMMs in one bankC. The distribution of data written across all the memory DIMMs and the processorD. The distribution of data written across all the memory DIMMs and the L2 cache
考题
An enterprise has plans to start adding IPv6 support. The initial deployment requires support from some IPv6 - only device s that need to access servers that support only IPv4.Which of the following tools would be most appropriate?()A. Native IPv6B. Point - to -point tunnelsC. Multipoint tunnelsD. NAT - PT
考题
Which two servers support memory extension technology and give list?()A、 B200B、 C210C、 B250D、 C260E、 C460
考题
A customer has a requirement for a server to run Windows Server 2003 Enterprise Edition and Exchange 2003 Enterprise Edition. It has been determined that 4GB RAM will be needed. The customer is trying to decide between the two following configurations: (1)An IBM xSeries x366 with 4 Xeon MP processors and 4 x 1GB memory DIMMs. (2)An IBM xSeries x445 with 4 Xeon MP processors and 8 x 1GB memory DIMMs. Which question should be asked to guide the customer in selecting the correct memory configuration?()A、Is rack space an issue?B、Is there a high cache-hit ratio?C、Is this a mission-critical application?D、Are there plans to expand the memory to 8GB in the future?
考题
During a presentation on the p5 machines, a customer asks the pSeries technical specialist a question regarding the differences between POWER4+ and POWER5. In addition to new advanced power management, SMT, and larger L2 and L3 caches in POWER5, which of the following describes some of the key improvements in POWER5?()A、Micro-Partitioning support and the L3 controller is now between L2 and main memory.B、Dynamic partitioning support and the L3 controller is now between L2 and main memory.C、Micro-Partitioning support and the L3 controller is no longer between L2 and main memory.D、Dynamic partitioning support and the L3 controller is no longer between L2 and main memory.
考题
A small business currently has four separate servers, three of which perform low-overhead tasks with small memory footprints. How could the company BEST reduce power consumption among these four servers, while not sacrificing functionality?()A、Enable each server’s Cool ’n’ Quiet and/or SpeedStep functionality so that processing power is conserved.B、Enforce auto-shutdown routines on all four servers for after-hours power saving while the office is closed.C、Consolidate the four servers onto the best two,combining them logically by tasks and memory consumption.D、Consolidate the four servers onto the most powerful machine using virtualization.
考题
A new computer is displaying the wrong amount of memory. Which of the following may be the cause?()A、The module is installed backwards.B、A USB device is using some memory.C、An onboard video card is using some memory.D、The CPU is using some memory.
考题
An administrator is adding additional memory into a server that registers 1GB of memory in the OS and notices that the system has 2GB of memory physically installed; however, the server only shows 1GB of memory during POST. Which of the following is the MOST likely reason for this?()A、 The OS does not support more than 1GB of memory.B、 The system memory has different manufacture dates.C、 Two of the memory sticks are defective.D、 The server is using memory interleaving.
考题
Which of the following defines memory interleaving?()A、The distribution of data written across all the memory DIMMs and the L1 cacheB、The distribution of data written across all the memory DIMMs in one bankC、The distribution of data written across all the memory DIMMs and the processorD、The distribution of data written across all the memory DIMMs and the L2 cache
考题
Some xSeries servers support 4-way memory interleaving and some support 2-way interleaving. In both types of interleaving, the data is accessed 256 bits at a time. How is this 256-bit data access achieved with 2-way interleaving?()A、The DIMMs used for 2-way interleaving are double the width of DIMM used in 4-way interleaving.B、The DIMMs used for 2-way interleaving are 64-bit wide and data bits are accessed both on the rising edge and falling edge of the clock cycle.C、The DIMMs used for 2-way interleaving are 32-bit wide and data bits are accessed both on the rising edge and falling edge of the clock cycle.D、The DIMMs used for 2-way interleaving are double the width and data bits are accessed both on the rising edge and falling edge of the clock cycle.
考题
An existing IBM customer has some iSeries servers in their environment. The customer is adding an x366 server with an RSA-II installed for their Microsoft Client/Server applications. The customer wants to consolidate the storage and centralize the backup of the iSeries and xSeries platforms. Which of the following will accomplish this?()A、Share the data over the Ethernet LAN.B、Install the IXA Adapter in the iSeries server.C、Install the IXA Adapter in the xSeries server.D、Attach both servers to an IXS switch.
考题
A Dell customer decided to use IBM Director and xSeries to manage their servers. They purchased 10 IBM x336 servers and they already have 75 various Dell servers. Which TWO steps need to be verified to be able to manage the mixed environment with IBM Director?()A、Verify that the Dell systems have TCP/IP enabledB、Verify that the systems are running the IBM Director AgentC、Verify that the managed systems are SMBIOS 2.1 and WfM 2.0 compliantD、Verify that the Dell systems have at least a 1GB of memory installedE、Install an SNMP agent on the Dell systems as IBM Director cannot manage Industry Standard non-IBM servers
考题
A customer needs to deploy ten dual processor Xeon servers. Six servers will be running Linux and Apache, and the other four will be Citrix presentation servers. The customer’s main concerns are the rack space and the option to have SATA drives. The maximum memory required is 8GB. Which of the following options will provide the best price and performance?()A、Ten x306’s with internal SATA drivesB、Five x346’s with internal SATA drives and VMWare ESX ServerC、Five x366’s partitioned into two VMs each with VMWare ESX ServerD、Ten x336’s with internal SATA drives
考题
A 4-way x445 server with 2GB of memory running Windows 2003 Server with Exchange 2003 is performing poorly. Users are complaining of slow response times when accessing their email. Which subsystem should be checked first as a potential bottleneck?()A、ProcessorsB、Memory subsystemC、Storage subsystemD、Network connectivity
考题
A customer has purchased an IBM BladeCenter H chassis and needs the following servers: --Two HS21 blade servers each with 8GB memory and 2 drives --Two HS21 blade servers each with 24GB memory and 2 drives --Two LS21 blade servers each with 2GB memory and 2 Hot-Swap SCSI drives How many total server bays will be required for this configuration?()A、6B、8C、10D、12
考题
A 2-way interleaved DDR configuration and a 4-way interleaved SDRAM configuration will produce which of the following?()A、They will have the same memory bandwidth.B、2-way will provide higher memory bandwidth than 4-way.C、4-way will provide higher memory bandwidth than 2-way.D、4-way will provide higher memory bandwidth but only on an x445.
考题
Which memory technology combination on the x255 will allow for two memory banks to fail while maintaining the server?()A、Memory mirroring and hot swap memoryB、Memory mirroring and hot spare memoryC、Four way memory interleaving and chipkillD、Four way memory interleaving and memory mirroring
考题
Your network consists of a single Active Directory site that includes two network segments. Thenetwork segments connect by using a router that is RFC 1542 compliant. You plan to use Windows Deployment Services (WDS) to deploy Windows Server 2008 R2 servers. All new servers support Pre-Boot Execution Environment (PXE). You need to design a deployment strategy to meet the following requirements: èSupport Windows Server?2008 R2 èDeploy the servers by using WDS in both network segments èMinimize the number of servers used to support WDS What should you include in your design?() A、Deploy one server. Install WDS and DHCP on the server. Configure the IP Helper tables on therouterbetween the network segments.B、Deploy two servers. Install WDS and DHCP on both servers. Place one server on each of the network segments. Configure both servers to support DHCP option 60.C、Deploy two servers. Install WDS and DHCP on both servers. Place one server on each of the network segments. Configure both servers to support DHCP option 252.D、Deploy two servers. Install WDS and DHCP on one server. Install DHCP on the other server. Place one server on each of the network segments. Configure both servers to support DHCP option60.
考题
单选题Which of the following defines memory interleaving?()A
The distribution of data written across all the memory DIMMs and the L1 cacheB
The distribution of data written across all the memory DIMMs in one bankC
The distribution of data written across all the memory DIMMs and the processorD
The distribution of data written across all the memory DIMMs and the L2 cache
考题
单选题A new computer is displaying the wrong amount of memory. Which of the following may be the cause?()A
The module is installed backwards.B
A USB device is using some memory.C
An onboard video card is using some memory.D
The CPU is using some memory.
考题
单选题During a presentation on the p5 machines, a customer asks the pSeries technical specialist a question regarding the differences between POWER4+ and POWER5. In addition to new advanced power management, SMT, and larger L2 and L3 caches in POWER5, which of the following describes some of the key improvements in POWER5?()A
Micro-Partitioning support and the L3 controller is now between L2 and main memory.B
Dynamic partitioning support and the L3 controller is now between L2 and main memory.C
Micro-Partitioning support and the L3 controller is no longer between L2 and main memory.D
Dynamic partitioning support and the L3 controller is no longer between L2 and main memory.
考题
单选题A 2-way interleaved DDR configuration and a 4-way interleaved SDRAM configuration will produce which of the following?()A
They will have the same memory bandwidth.B
2-way will provide higher memory bandwidth than 4-way.C
4-way will provide higher memory bandwidth than 2-way.D
4-way will provide higher memory bandwidth but only on an x445.
考题
单选题A small IT department is deploying Power 720 servers exploiting virtualization technologies. Each Power 720 will have two partitions, one with 6 cores and one with 2 cores, and both partitions having 32GB of memory each. Live Partition Mobility is being considered at some point in the future. What is the minimum AIX Edition required to support the customer?()A
AIX Basic EditionB
AIX Express EditionC
AIX Standard EditionD
AIX Enterprise Edition
考题
单选题An enterprise has plans to start adding IPv6 support. The initial deployment requires support from some IPv6 - only device s that need to access servers that support only IPv4. Which of the following tools would be most appropriate?()A
Native IPv6B
Point - to -point tunnelsC
Multipoint tunnelsD
NAT - PT
考题
多选题Which two servers support memory extension technology and give list?()AB200BC210CB250DC260EC460
考题
单选题An existing IBM customer has a few pSeries servers running DB2 on AIX in their environment. The DB2 application contains the database for an order entry application. An xSeries SQL database server replicating from DB2 is added for off-line analysis purposes. The customer wants to know if consolidating the storage and centralized backup is possible. What are the options available to accomplish this?()A
pSeries and xSeries use different file systems. Consolidating Storage and backup is not achievable.B
Consolidation is possible by connecting pSeries local storage to the xSeries SQL server using the IXA adapter.C
Storage consolidation can be achieved by connecting the pSeries and xSeries servers to a common DS4000 storage server.D
Storage consolidation is only achievable when raw file systems are used by the databases and both servers run the same Linux file system (e.g., EXT3 or Reiser).
考题
单选题Which memory technology combination on the x255 will allow for two memory banks to fail while maintaining the server?()A
Memory mirroring and hot swap memoryB
Memory mirroring and hot spare memoryC
Four way memory interleaving and chipkillD
Four way memory interleaving and memory mirroring
考题
单选题An administrator is adding additional memory into a server that registers 1GB of memory in the OS and notices that the system has 2GB of memory physically installed; however, the server only shows 1GB of memory during POST. Which of the following is the MOST likely reason for this?()A
The OS does not support more than 1GB of memory.B
The system memory has different manufacture dates.C
Two of the memory sticks are defective.D
The server is using memory interleaving.