网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
A customer RFP requires installation of an open system SAN and migration of 40 TB currently residing on ten UNIX servers (on internal server disk). The Service Level Agreement (SLA) requires no more than five minutes per week of planned downtime for backup.  Which IBM System Storage solution is the most cost effective()
A

an IBM System Storage DS8700 with LTO tape drive

B

an IBM System Storage DS8700 with FlashCopy Manager

C

an IBM XIV Storage System

D

an IBM XIV Storage System with SAN Volume Controller


参考答案

参考解析
解析: 暂无解析
更多 “单选题A customer RFP requires installation of an open system SAN and migration of 40 TB currently residing on ten UNIX servers (on internal server disk). The Service Level Agreement (SLA) requires no more than five minutes per week of planned downtime for backup.  Which IBM System Storage solution is the most cost effective()A an IBM System Storage DS8700 with LTO tape driveB an IBM System Storage DS8700 with FlashCopy ManagerC an IBM XIV Storage SystemD an IBM XIV Storage System with SAN Volume Controller” 相关考题
考题 A customer has just received three enterprise systems that support a total of 48 LPARs. Which installation method expedite the process?() A.Network installation managerB.Boot from installation mediaC.A migration installD.Copy the system using the HMC

考题 An IBM Business Partner suggests an IBM System Storage DS8000 to a customer with a SAN   that is now configured with an EMC Symmetrix subsystem disk.  The customer wants to determine if new HBAs and software upgrades are needed on the servers if the EMC storage is replaced by the DS8000 What document must be carefully read to help address the customer’s concerns()A、IBM System Storage DS8000: Host Systems Attachment GuideB、DS8000 Interoperability MatrixC、IBM System Storage DS8000: Introduction and Planning GuideD、IBM System Storage Solution Handbook

考题 A banking customer deployed an IBM BladeCenter chassis with one Brocade 8Gb SAN switch module. The customer requires an 8Gb uplink or higher. Which configuration will meet this request?()A、Brocade Enterprise 20-port 8Gb SAN switch module B、Brocade 20-port 8Gb SAN switch module and Brocade Advanced Performance Monitoring for IBM BladeCenter share C、Brocade Enterprise 10-port 8Gb SAN switch module D、Brocade 10-port 8Gb SAN switch module and Brocade Advanced Performance Monitoring for IBM BladeCenter

考题 A customer recently installed new a SAN with an IBM System Storage DS8700 and several open systems servers to address a need for storage consolidation and still provide good response time. They have asked the Business Partner technical representative for the most complete IBM product that would allow them to do performance reporting of the new SAN environment.  What is the best solution()A、Tivoli Storage ManagerB、Tivoli Storage Productivity Center for DiskC、Tivoli Storage Productivity Center Basic EditionD、Tivoli Storage Productivity Center Standard Edition

考题 A customer has an existing DS5300 system attached to two Brocade switches with eight Windowsservers. The customer wants to add their System i p750 server to this SAN. From the followingchoices what is the simplest and least expensive solution for this customer?()A、add twofibre HBAs to the System i and connect to the SANB、add twofibre HBAs to the System i and connect to the Windows ServersC、add twofibre HBAs to the System i and connect to the System i using VIOSD、add two SAS HBAs to the Systemi array and connect directly to the DS5300

考题 A storage specialist is proposing a solution consisting of an IBM System Storage TS3200 TapeLibrary and a SAN Volume Controller, both of which are being added to a customer’s existing SANenvironment for the first time. Which of the following should be completed before the proposal ispresented to the customer?()A、TDAB、Capacity MagicC、business case reviewD、SAN configuration review

考题 A proposed server architecture includes SAN LUNs being presented to client LPARs using shared HBAs to reduce infrastructure cost. The customer requires minimal management efforts for the dual VIO Servers.   Which technology is recommended for this proposal?()A、NPIVB、vSCSIC、Arbitrated loopD、Converged adapter

考题 A customer recently installed new SAN with an IBM System Storage DS8300 and several open systems servers to address a need for storage consolidation and still provide  good response time. They have asked the Business Partner technical representative for the most complete IBM product that would allow them to do performance reporting of the new SAN environment.  What is the best solution()A、Tivoli Storage ManagerB、Total Productivity Productivity Center for DiskC、Total Productivity Center Basic EditionD、Total Storage Productivity Center Standard Edition

考题 A customer requires management capabilities for installed pSeries systems via a Microsoft Windows system. Which of the following should be considered?()A、TSMB、PSSPC、WebSMD、LoadLeveler

考题 A customer requires two 12X loops on their new POWER7 system. What is the smallest system that will support two loops?()A、Power 710B、Power 720C、Power 730D、Power 740

考题 Which of the following environments is most closely addressed by the N series N3600?()A、a customer that requires block level storage B、a customer that requires CIFS and AIX NFS environments C、a customer that requires good scalability and performance D、a customer that needs to consolidate multiple storage controllers under a single interface

考题 A customer has just received three enterprise systems that support a total of 48 LPARs. Which installation method expedite the process?()A、Network installation managerB、Boot from installation mediaC、A migration installD、Copy the system using the HMC

考题 A customer plans to order several new pSeries systems and is concerned that the additional heat load may overwhelm the current air-handling system.  How might the pSeries technical specialist aid the customer in addressing their concern?()A、Direct the customer to the Installation Guide for each system to identify the power requirements.B、Direct the customer to engage their site personnel to ensure the proper power connectors are provided to support the systems.C、Direct the customer to the Site and Hardware Planning Information and review the system requirements for each new pSeries system.D、Direct the customer to the Site and Hardware Planning Information to confirm that enough space is available in the rack to allow for proper airflow.

考题 An IBM Business Partner sells an IBM System Storage DS8700 to a customer.  Who is responsible for the installation and set up of the storage server()A、purchasing customerB、IBM Installation Readiness TeamC、IBM Customer EngineerD、IBM Business Partner

考题 A customer with an IBM Power System running AIX is using an IBM System Storage DS8100 inLocation A, and an IBM System Storage DS5100 in Location B. The distance between Location Aand Location B is 25 kilometers. The customer wants a redundant copy of the data inLocation Bfor disaster recovery. Which of the following solutions will best satisfy this requirement?()A、install FlashCopy on the DS8100 B、install SAN Volume Controllers with FlashCopyC、install SAN Volume Controllers with Metro Mirror D、install Global Mirror on the DS8100 and Enhanced Remote Mirror on the DS5100 

考题 A customer has a mission-critical application with redundant fabrics. The customer plans to replace older EMC Symmetrix 8830 systems with an IBM System Storage DS8700 and an IBM SAN Volume Controller (SVC).  Which statement best describes the way to minimize the impact of data migration on the production environment()A、the production environment does not require an outageB、the production environment requires an outage to install the SVCC、the production environment requires an outage to install the DS8700D、the production environment requires an outage to remove the EMC systems

考题 Acustomer RFP requires installation of an open system SAN and migration of 40 TBs currently residing on ten UNIX servers (on native server disk). The Service Level Agreement (SLA) requires no more than five minutes per week of planned downtime for backup.  Which IBM System Storage solution should the sales specialist propose()A、an IBM System Storage DS8100 with TS1120 Tape DriveB、an IBM System Storage DS8100 with FlashCopyC、an IBM System Storage DS6800 with TS7510 Virtualization EngineD、an IBM System Storage DS6800 with FlashCopy

考题 Which of the following situations would suggest to a System x Sales Specialist that the customer could benefit from an iSCSI solution?()A、The customer is looking for a fibre SAN solution to increase reliability and performance.B、The customer wants to implement an energy-efficient solution to comply with their Go Green initiative.C、The customer is cost-conscious and is looking for a centralized storage solution.D、The customer is a large telecommunications firm and is looking to centralize storage for all their System x,System p,and mainframe servers.

考题 Cer-tech .com hosts a single Active Directory domain. All servers have Windows Server 2008. You areinstructed to install an iSCSI storage area network (SAN) for a group of file servers. Corporate securitypolicy requires that all data communication to and from iSCSI SAN must be very secure. You are assignedthe task to implement the highest security available for communications to and from the iSCSI SAN. Whatshould you do to achieve this task?()A、Create a Group Policy Object (GPO) to enable System objectsB、Create a Microsoft Challenge Handshake Authentication Protocol (MS-CHAPv2) authentication in iSCSIInitiator Properties.C、Open iSCSI Initiator Properties and implement IPSec security. Set up inbound and outbound rules byusing Windows FirewallD、Open iSCSI Initiator Properties and implement Secure Mode transition. Set outbound and inbound rulesby using Windows Defender

考题 A customer RFP requires installation of an open system SAN and migration of 40 TB currently residing on ten UNIX servers (on internal server disk). The Service Level Agreement (SLA) requires no more than five minutes per week of planned downtime for backup.  Which IBM System Storage solution is the most cost effective()A、an IBM System Storage DS8700 with LTO tape driveB、an IBM System Storage DS8700 with FlashCopy ManagerC、an IBM XIV Storage SystemD、an IBM XIV Storage System with SAN Volume Controller

考题 单选题Acustomer RFP requires installation of an open system SAN and migration of 40 TBs currently residing on ten UNIX servers (on native server disk). The Service Level Agreement (SLA) requires no more than five minutes per week of planned downtime for backup.  Which IBM System Storage solution should the sales specialist propose()A an IBM System Storage DS8100 with TS1120 Tape DriveB an IBM System Storage DS8100 with FlashCopyC an IBM System Storage DS6800 with TS7510 Virtualization EngineD an IBM System Storage DS6800 with FlashCopy

考题 单选题An SMB customer requires a tower server with 2TB of internal storage. The customer has requested a low cost solution.  What IBM System x server would satisfy this criteria?()A x3250B x3200C x3650D x3400

考题 单选题A Business Partner is proposing the installation an IBM XIV Storage System at a customer location.  What is the best time to discuss floor space requirements for the solution()A during the Technical Delivery and AssessmentB during installation of the equipmentC prior to delivery of the XIVD during the solution proposal

考题 单选题A customer has a mission-critical application with redundant fabrics. The customer plans to replace older EMC Symmetrix 8830 systems with an IBM System Storage DS8700 and an IBM SAN Volume Controller (SVC).  Which statement best describes the way to minimize the impact of data migration on the production environment()A the production environment does not require an outageB the production environment requires an outage to install the SVCC the production environment requires an outage to install the DS8700D the production environment requires an outage to remove the EMC systems

考题 单选题A banking customer deployed an IBM BladeCenter chassis with one Brocade 8Gb SAN switch module. The customer requires an 8Gb uplink or higher. Which configuration will meet this request of the following?()A Brocade Enterprise 20-port 8Gb SAN switch moduleB Brocade 20-port8Gb SAN switch module and Brocade Advanced Performance Monitoring for IBM BladeCenterC Brocade Enterprise 10-port 8Gb SAN switch moduleD Brocade 10-port8Gb SAN switch module and Brocade Advanced Performance Monitoring for IBM BladeCenter

考题 单选题A customer has just received three enterprise systems that support a total of 48 LPARs. Which installation method expedite the process?()A Network installation managerB Boot from installation mediaC A migration installD Copy the system using the HMC

考题 单选题Which of the following situations would suggest to a System x Sales Specialist that the customer could benefit from an iSCSI solution?()A The customer is looking for a fibre SAN solution to increase reliability and performance.B The customer wants to implement an energy-efficient solution to comply with their Go Green initiative.C The customer is cost-conscious and is looking for a centralized storage solution.D The customer is a large telecommunications firm and is looking to centralize storage for all their System x,System p,and mainframe servers.