网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
An administrator needs to replace a failed internal disk in a mirrored rootvg. Which of the following is one of the steps that must be followed()
A

Deallocate rootvg mirror

B

Use hot replace manager

C

Break rootvg mirror

D

Deallocate LPs from failed disk


参考答案

参考解析
解析: 暂无解析
更多 “单选题An administrator needs to replace a failed internal disk in a mirrored rootvg. Which of the following is one of the steps that must be followed()A Deallocate rootvg mirrorB Use hot replace managerC Break rootvg mirrorD Deallocate LPs from failed disk” 相关考题
考题 You are the network administrator for . You manage a Windows Server 2003 computer that functions as a file server.The data volume on the server is configured as a software RAID-5 array. One of disks that contain the data volume fails. You replace the failed disk. You start the Disk Management utility and view the status listed in the following table.You need to restore fault tolerance.Which two actions should you perform?() (Each correct answer presents part of thesolution. Choose two.)A. Create a striped set that includes Disk1 and Disk2.B. Initialize Disk3 and convert it to a dynamic disk.C. Reactivate the RAID-5 array volume.D. Repair the RAID-5 array volume to include Disk3.E. Initiailize Disk3 and configure it as a basic disk.F. Reactivate the missing disk.

考题 An administrator needs to load additional disk drivers on the VIOS in order to attach to the SAN. Which of the following will enable this?()A、 run updateios B、 run cfgdriver C、 run oem_setup_env D、 run driver_install 

考题 A system administrator has run topas on a server.  The output shows that the %iowait of the system is 60% and that most of the disk activity is on hdisk0.  Which of the following procedures should be performed to fix this problem?()A、 Replace the hard disk with a faster disk drive. B、 Add another paging space on another hdisk. C、 Spread the data hdisk0 across several hdisks. D、 Nothing, since %iowait is a measurement of CPU time.

考题 A server contains a 3 disk RAID 5 array. The red LED is illuminated on one of the drives. Which of the following should the server administrator perform?()A、Replace the driveB、Restore the drive from backupC、Reboot the serverD、Reconfigure RAID 5 to RAID 10

考题 A user reports that their hard drive has failed and needs to be replaced. Which of the following should the technician do FIRST?()A、Run the hard disk manufacturer’s diagnostic programB、Re-image the driveC、Replace the hard drive and load WindowsD、Ask the user diagnostic questions

考题 An administrator is attempting to start a server from a bootable Linux disk but instead the server boots into Windows. Which of the following is the MOST likely reason for this?()A、The system needs to boot to Windows first, prior to booting into Linux.B、The OS settings are not set properly for Linux support.C、The boot order is set incorrectly in the BIOS.D、The Linux disk is not supported in a Windows environment.

考题 An administrator needs to recover an HMC due to a failed disk. The disk has been replaced, allowing the administrator to reinstall the HMC back to the required release of software. Backups of both the HMC Console Data and Upgrade Data are available. After reloading the HMC with the Recovery DVDs, what are the next steps to restore the HMC configuration?()A、Use the 'HMC Management Restore HMC Data' option to first restore just the HMC Data..B、Use the 'HMC Management Restore Upgrade Data' option to first restore just the Upgrade Data.C、Use the 'HMC Management Restore HMC Data' option to first restore the HMC Data and then the Upgrade Data.D、Use the 'HMC Management Restore Upgrade Data' option to first restore the Upgrade Data, and then the HMC Data.

考题 An administrator has mirrored the root volume group to a second disk, but ’bootlist’ is failing to correctly add the second disk.  What is the likely cause of the problem?()  A、The administrator has failed to run ’bosboot -ad 2nd disk’ prior to the bootlist command.B、The administrator has failed to run ’bootinfo -B 2nd disk’ prior to the bootlist command.C、The administrator has failed to run ’mirrorvg -m rootvg 2nd disk’ prior to the bootlist command.D、The administrator has failed to run ’bosboot -ad /dev/ipldevice 2nd disk’ prior to the bootlist command.

考题 A System p administrator needs to replace a failed internal disk in a mirrored rootvg.  Which of thefollowing is one of the steps that would need to be followed()A、Run cfgmgrB、odmdelete CuAtC、exportvg rootvgD、Deallocate LPs from failed disk

考题 A system administrator needs to replace a mirrored disk.  After performing the proper removal process and replacing the disk, which of the following set of commands should be performed to bring the disk back into production?()A、 reboot, mklvcopy, syncvg B、 cfgmgr -vl ssar, chvg -va, syncvg C、 cfgmgr, extendvg, syncvg D、 extendvg, mklvcopy, syncvg

考题 You are the network administrator for The network consists of a single Active Directory domain named All servers run Windows Server 2003. A server named TestKing7 runs Microsoft SQL Server and hosts several mission critical databases. TestKing7 contains a mirrored volume. A routine review of TestKing7 shows failed redundancy on the mirrored volume. TestKing7 is still running and the databases are still functioning correctly. You need to correct the error and restore redundancy. What should you do first?()A、Initialize the failed disk.B、Select the failed disk and reactivate the diskC、Defragment the mirrored volume.D、Perform a disk cleanup on the mirrored volume.

考题 You are the network administrator for your company. All network servers run Windows Server 2003. One of your servers contains a RAID-5 volume. Routine monitoring reveals a failed disk in the set. The server is running and users are connecting to shared folders on the RAID-5 volume. You shut down the server and replace the failed disk. Now you need to ensure that the RAID-5 volume is redundant. What should you do? ()A、Initialize the new disk. Select the failed region and then select the Repair Volume option.B、Import the foreign disk. Select the failed region and then select the Repair Volume option.C、Initialize the new disk. Select the failed region and then select the Reactivate Disk option.D、Import the foreign disk. Select the failed region and then select the Reactivate Disk option.

考题 An administrator needs to allocate additional disk space on a Windows 2000 Professional computer. Disk space is low and additional applications must be installed. Due to time constraints the administrator elects to add an additional hard disk instead of replacing the current one and reinstalling all the currently installed applications. The computer has two dynamic hard drives.   How can the administrator extend the existing volume with the space of a newly added hard drive?()A、Configure a Simple volume.B、Configure a Spanned volume.C、Configure a Striped volume.D、Configure a Striped volume with parity.E、By using NTFS version 5.

考题 An IT director needs to deploy 3 partitions, each using dedicated internal boot disk. Which system will support the customer requirement using the least amount of rack space?()A、Power 770 serversB、Power 750 serversC、Power 755 serversD、Power 720 servers

考题 单选题A system administrator has run topas on a server.  The output shows that the %iowait of the system is 60% and that most of the disk activity is on hdisk0.  Which of the following procedures should be performed to fix this problem?()A  Replace the hard disk with a faster disk drive. B  Add another paging space on another hdisk. C  Spread the data hdisk0 across several hdisks. D  Nothing, since %iowait is a measurement of CPU time.

考题 单选题An administrator needs to load additional disk drivers on the VIOS in order to attach to the SAN. Which of the following will enable this?()A  run updateios B  run cfgdriver C  run oem_setup_env D  run driver_install 

考题 单选题You have a computer that runs Windows 7. You perform regular data backups and system image backups.The computer experiences a hard disk failure. You replace the failed hard disk. You need to recover thecomputer to the previous Windows 7 environment. You start the computer from the Windows 7 installationmedia. Which recover option should you select?()A Command PromptB Startup RepairC System Image RecoveryD System Restore

考题 单选题Which of the following is a benefit of ASM fast disk resync?()A  Failed disks are taken offline immediately but are not dropped.B  Disk data is never lost.C  By default, the failed disk is not dropped from the disk group ever, protecting you from loss of that disk.D  The failed disk is automatically reformatted and then resynchronized to speed up the recovery process.E  Hot spare disks are automatically configured and added to the disk group.

考题 单选题A system administrator needs to replace a mirrored disk.  After performing the proper removal process and replacing the disk, which of the following set of commands should be performed to bring the disk back into production?()A  reboot, mklvcopy, syncvg B  cfgmgr -vl ssar, chvg -va, syncvg C  cfgmgr, extendvg, syncvg D  extendvg, mklvcopy, syncvg

考题 单选题Which of the following is a benefit of ASM fast disk resync?()A Failed disks are taken offline immediately but are not dropped.B Disk data is never lost.C By default, the failed disk is not dropped from the disk group ever, protecting you from loss of that disk.D The failed disk is automatically reformatted and then resynchronized to speed up the recovery process.E Hot spare disks are automatically configured and added to the disk group.

考题 单选题You are the network administrator for All network servers run Windows Server 2003. One of your servers, TestKingSrv1, contains a RAID-5 volume. Routine monitoring reveals a failed disk in the set. TestKingSrv1 is running and users are connecting to shared folders on the RAID-5 volume. You shut down the server and replace the failed disk. Now you need to ensure that the RAID-5 volume is redundant. What should you do?()A Import the foreign disk that is to replace the failed disk. Select the failed region and then select the Repair Volume option.B Initialize the new disk that is to replace the failed disk. Select the failed region and then select the Reactive Disk option.C Initialize the new disk that is to replace the failed disk. Select the failed region and then select the Repair Volume option.D Import the foreign disk that is to replace the failed disk. Select the failed region and then select the Reactive Disk option.

考题 单选题An administrator has mirrored the root volume group to a second disk, but ’bootlist’ is failing to correctly add the second disk.  What is the likely cause of the problem?()A The administrator has failed to run ’bosboot -ad 2nd disk’ prior to the bootlist command.B The administrator has failed to run ’bootinfo -B 2nd disk’ prior to the bootlist command.C The administrator has failed to run ’mirrorvg -m rootvg 2nd disk’ prior to the bootlist command.D The administrator has failed to run ’bosboot -ad /dev/ipldevice 2nd disk’ prior to the bootlist command.

考题 单选题A system administrator has a failed disk drive that is mirrored to another disk drive. They successfully removed the logical volume copies off of the failed disk drive. Which of the following commands should be used to remove the failed disk drive from the volume group?()A chvgB rmdevC reducevgD exportvg

考题 单选题You are the network administrator for. You are the administrator of a Windows Server 2003 computer named TestKing3. Newly hired employees recently started storing files on TestKing3. Now users report that Testking3 is responding much slower than it did before the additional users were added. You suspect the disk subsystem needs to be upgraded to accommodate the additional user load. You need to confirm whether the disk subsystem on TestKing3 needs to be upgraded. What should you do?()A Configure a Performance Logs and Alerts on the %Free space counter.B Use Device Manager to populate volume settings and examine the properties of the disk drives on TestKing3.C Use Event View to examine the system logs and search the system logs for event logs for events generated by the disk event source.D Use System Monitor to monitor counters based on the PhysicalDisk object

考题 单选题A user reports that their hard drive has failed and needs to be replaced. Which of the following should the technician do FIRST?()A Run the hard disk manufacturer’s diagnostic programB Re-image the driveC Replace the hard drive and load WindowsD Ask the user diagnostic questions