网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
Companycom is implementing a pair of Virtual IO Servers to service four LPARs. If each operating system image requires 15GB of disk space, what is the minimum amount of SCSI resource necessary?()
A

Two SCSI paths and two 73GB SCSI disks

B

Two SCSI paths and two 36GB SCSI disks

C

Four SCSI paths and four 73GB SCSI disks

D

Two dual port SCSI RAID adapters with two 73GB SCSI disks


参考答案

参考解析
解析: 暂无解析
更多 “单选题Companycom is implementing a pair of Virtual IO Servers to service four LPARs. If each operating system image requires 15GB of disk space, what is the minimum amount of SCSI resource necessary?()A Two SCSI paths and two 73GB SCSI disksB Two SCSI paths and two 36GB SCSI disksC Four SCSI paths and four 73GB SCSI disksD Two dual port SCSI RAID adapters with two 73GB SCSI disks” 相关考题
考题 A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to a RAID controller. The system administrator has decided to configure all six drives in a RAID 5 array.How much usable disk space will this array have?()A.288GBB.360GBC.432GBD.728GB

考题 A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to a RAID controller. The system’s administrator has decided to mirror two drives for the operating system. Which of the following is the maximum space the administrator will have remaining to use for data when using RAID 0?()A、292GBB、438GBC、584GBD、728GB

考题 Companycom is implementing a pair of Virtual IO Servers to service four LPARs. If each operating system image requires 15GB of disk space, what is the minimum amount of SCSI resource necessary?()A、Two SCSI paths and two 73GB SCSI disksB、Two SCSI paths and two 36GB SCSI disksC、Four SCSI paths and four 73GB SCSI disksD、Two dual port SCSI RAID adapters with two 73GB SCSI disks

考题 Attaching to a SCSI storage system through redundant paths will provide which of the following?()A、The ability to interleave writes to the arrayB、High Availability and failoverC、LUN sharing via Target Mode SCSI on the storage systemD、A greater number of LUNS available on the same storage system

考题 Companycom is about to purchase a POWER5 Enterprise server which requires two Ethernet ports and two disks for each of the four LPARs. It has been configured and validated using the IBM eConfig tool. Which of the following is very important to verify in addition to the eConfig validation?()A、Total number of SCSI adaptersB、Total number of Ethernet adaptersC、Total number of Ethernet adapters and number of SCSI paths per LPARD、Total number of SCSI paths available and total number of SCSI adapters

考题 What are the two parallel SCSI specifications?()A、 Up to 25 m bus lengthB、 Only one device per SCSI busC、 Up to 16 devices per SCSI busD、 Half-duplex operationE、 Full-duplex operation

考题 You ran out of space and added a eighth disk to your SCSI-1 system. When you try to start, the system no longer boots. What is most likely the cause of this problem?()A、 SCSI-1 supports only 8 devices including the adaptor.B、 SCSI-1 supports only 6 disks per adaptor.C、 There is a SCSI-ID conflict that causes that problem.D、 You forgot to set the SCSI-ID #8 for the new disk.

考题 A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to a RAID controller. The system administrator has decided to configure all six drives in a RAID 5 array. How much usable disk space will this array have?()A、288GBB、360GBC、432GBD、728GB

考题 Companycom will be using the Virtual IO Server to share both FC and Ethernet adapters among multiple LPARs. The customer is using mostly web services in the LPARs. Which of the following should be considered?()A、Shared Ethernet Adapters and Virtual SCSI services require separate Virtual IO Servers.B、Virtualized adapters require essentially the same Virtual IO Server resources regardless of adapter type.C、Shared Ethernet Adapters require significantly more Virtual IO Server resources than Virtual SCSI services.D、Virtual SCSI services require significantly more Virtual IO Server resources than Shared Ethernet Adapters.

考题 What type of configuration can provide the best availability in a Virtual IO Server environment?()A、Provide multiple paths to all resources through 2 or more Virtual IO ServersB、Mirror all disk resources on the Virtual IO Server to present to the client LPARC、Mirror all disk resources on the client LPAR to the shared SCSI on the Virtual IO ServerD、Trunk multiple Ethernet adapters on the Virtual IO Server to a single Shared Ethernet Adapter (SEA)

考题 Companycom LPAR that is using a Virtual IO Server needs to be more highly available. How can this be accomplished using APV features?()A、Reallocate the Virtual IO Server disks to the user LPARB、Create a stripe-group within the Virtual IO Server to protect against disk failureC、Reconfigure the user LPAR to use both locally owned disk and a Virtual SCSI diskD、Create a second Virtual IO Server and reconfigure the user LPAR to mirror across both Virtual IO Servers

考题 Company.com is having trouble installing a fresh AIX image onto a newly defined partition on a p5-520. The assignment of the adapters to the each of the partitions is as follows: Fibre Channel Card 01 - partition one - required  Fibre Channel Card 02 - partition one - required  SCSI adapter 01 - partition one - desired  IDE adapter 01 - partition one - required  Ethernet adapter 01 - partition one - required  Ethernet adapter 01 - partition two - required  SCSI adapter 02 - partition two - required  IDE adapter 01 - partition two - desired  Which of the following actions will enable the installation of the AIX image?()A、Change the IDE adapter from desired to required in partition two and restart the partition to release the resource.B、Purchase a SCSI DVD-ROM drive to connect to the SCSI adapter in partition two.C、Purchase an LTO tape drive so that a system image backup can be created to install a new AIX partition.D、Change the IDE adapter from required to desired in partition one and restart the partition to release the resource.

考题 Companycom wants to use Virtual SCSI disks to boot multiple operating systems from the same disk. How will the volumes appear in the Virtual IO Server and how will the logical volumes appear in the partition?()A、The Virtual SCSI disks are defined as logical volumes in the Virtual IO Server. The logical volumes appear as real devices (hdisks) in the client partitions. B、The Virtual IO adapters are connected to a virtual host bridge. On the Virtual IO Server they are vdisks, on the client partition, the exported disks are visible as virtual disks. C、The Virtual SCSI disks are represented in the ODM as a bus device whose parent is sysplanar0. Logical volumes will be assigned to the Virtual IO Server and virtual disks, vdisks, in the client partition. D、The Virtual IO adapters are represented as adapter devices with the virtual host bridge as their parent. On the Virtual IO Server they are vdisks attached to vscsi, on the client partition the exported disks are visible as virtual disks.

考题 单选题Companycom is about to purchase a POWER5 Enterprise server which requires two Ethernet ports and two disks for each of the four LPARs. It has been configured and validated using the IBM eConfig tool. Which of the following is very important to verify in addition to the eConfig validation?()A Total number of SCSI adaptersB Total number of Ethernet adaptersC Total number of Ethernet adapters and number of SCSI paths per LPARD Total number of SCSI paths available and total number of SCSI adapters

考题 单选题Companycom LPAR that is using a Virtual IO Server needs to be more highly available. How can this be accomplished using APV features?()A Reallocate the Virtual IO Server disks to the user LPARB Create a stripe-group within the Virtual IO Server to protect against disk failureC Reconfigure the user LPAR to use both locally owned disk and a Virtual SCSI diskD Create a second Virtual IO Server and reconfigure the user LPAR to mirror across both Virtual IO Servers

考题 单选题Companycom will be using the Virtual IO Server to share both FC and Ethernet adapters among multiple LPARs. The customer is using mostly web services in the LPARs. Which of the following should be considered?()A Shared Ethernet Adapters and Virtual SCSI services require separate Virtual IO Servers.B Virtualized adapters require essentially the same Virtual IO Server resources regardless of adapter type.C Shared Ethernet Adapters require significantly more Virtual IO Server resources than Virtual SCSI services.D Virtual SCSI services require significantly more Virtual IO Server resources than Shared Ethernet Adapters.

考题 单选题Companycom will be using the Virtual IO Server to share both FC and Ethernet adapters among multiple LPARs. The customer is using mostly web services in the LPARs. Which of the following should be considered?()A Shared Ethernet Adapters and Virtual SCSI services require separate Virtual IO Servers.B Virtualized adapters require essentially the same Virtual IO Server resources regardless of adapter type.C Shared Ethernet Adapters require significantly more Virtual IO Server resources than Virtual SCSI services.D Virtual SCSI services require significantly more Virtual IO Server resources than Shared Ethernet Adapters.

考题 多选题What are the two parallel SCSI specifications?()AUp to 25 m bus lengthBOnly one device per SCSI busCUp to 16 devices per SCSI busDHalf-duplex operationEFull-duplex operation

考题 单选题Company.com is having trouble installing a fresh AIX image onto a newly defined partition on a p5-520. The assignment of the adapters to the each of the partitions is as follows: Fibre Channel Card 01 - partition one - required  Fibre Channel Card 02 - partition one - required  SCSI adapter 01 - partition one - desired  IDE adapter 01 - partition one - required  Ethernet adapter 01 - partition one - required  Ethernet adapter 01 - partition two - required  SCSI adapter 02 - partition two - required  IDE adapter 01 - partition two - desired  Which of the following actions will enable the installation of the AIX image?()A Change the IDE adapter from desired to required in partition two and restart the partition to release the resource.B Purchase a SCSI DVD-ROM drive to connect to the SCSI adapter in partition two.C Purchase an LTO tape drive so that a system image backup can be created to install a new AIX partition.D Change the IDE adapter from required to desired in partition one and restart the partition to release the resource.

考题 单选题What type of configuration can provide the best availability in a Virtual IO Server environment?()A Provide multiple paths to all resources through 2 or more Virtual IO ServersB Mirror all disk resources on the Virtual IO Server to present to the client LPARC Mirror all disk resources on the client LPAR to the shared SCSI on the Virtual IO ServerD Trunk multiple Ethernet adapters on the Virtual IO Server to a single Shared Ethernet Adapter (SEA)

考题 单选题A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to a RAID controller. The system’s administrator has decided to mirror two drives for the operating system. Which of the following is the maximum space the administrator will have remaining to use for data when using RAID 0?()A 292GBB 438GBC 584GBD 728GB

考题 单选题Attaching to a SCSI storage system through redundant paths will provide which of the following?()A The ability to interleave writes to the arrayB High Availability and failoverC LUN sharing via Target Mode SCSI on the storage systemD A greater number of LUNS available on the same storage system

考题 单选题You create a virtual machine (VM) on a Windows Server 2008 R2 Hyper-V server. The VM has a single VHD file that is connected to an IDE controller. You need to add five new virtual disks to the VM. You must minimize the amount of virtual hardware. What should you do?()A Add the virtual disks to IDE Controller 0.B Add the virtual disks to an existing SCSI controller.C Remove the virtual DVD drive, and add the virtual disks to IDE Controller1.D Add five SCSI controllers to the VM, and add one virtual disk to each SCSI controller.

考题 单选题A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to a RAID controller. The system administrator has decided to configure all six drives in a RAID 5 array. How much usable disk space will this array have?()A 288GBB 360GBC 432GBD 728GB

考题 单选题A server consists of two 72GB SCSI drives and four 146GB SCSI drives. All drives are attached to RAID  controller. The system administrator has decided to configure all six drives in a RAID 5 array.  How much usable disk space will this array have?()A  288GBB  360GBC  432GBD  728GB

考题 单选题Companycom wants to use Virtual SCSI disks to boot multiple operating systems from the same disk. How will the volumes appear in the Virtual IO Server and how will the logical volumes appear in the partition?()A The Virtual SCSI disks are defined as logical volumes in the Virtual IO Server. The logical volumes appear as real devices (hdisks) in the client partitions. B The Virtual IO adapters are connected to a virtual host bridge. On the Virtual IO Server they are vdisks, on the client partition, the exported disks are visible as virtual disks. C The Virtual SCSI disks are represented in the ODM as a bus device whose parent is sysplanar0. Logical volumes will be assigned to the Virtual IO Server and virtual disks, vdisks, in the client partition. D The Virtual IO adapters are represented as adapter devices with the virtual host bridge as their parent. On the Virtual IO Server they are vdisks attached to vscsi, on the client partition the exported disks are visible as virtual disks.

考题 单选题You ran out of space and added a eighth disk to your SCSI-1 system. When you try to start, the system no longer boots. What is most likely the cause of this problem?()A  SCSI-1 supports only 8 devices including the adaptor.B  SCSI-1 supports only 6 disks per adaptor.C  There is a SCSI-ID conflict that causes that problem.D  You forgot to set the SCSI-ID #8 for the new disk.