站内搜索
IBM(000-062) 问题列表
问题 单选题Company.com has a two-way p5-520 that will be running three shared processor Micro-Partitions consuming 60 percent of system resources. Immediately prior to shipment, the customer discovered they need to run a fourth server that requires AIX 5L V5.2. Which of the following will satisfy this requirement?()A Change to a 4-way p5-550B Use Capacity on DemandC Configure a fourth logical partitionD Add memory to the configuration

问题 单选题Company.com would like to share CPU resources between AIX V5.3 and Linux partitions. Which solution would best satisfy this customer requirement?()A Micro-PartitioningB Partition Load ManagerC eWLMD Grid Toolbox

问题 单选题A technical specialist has installed a Host Bus Adapter (HBA) on a p5-550 server. The system has four AIX 5L V5.3 partitions and a Virtual I/O server. The HBA will be used to connect all four partitions to a DS8000 storage array. What else must be performed to make the storage available to the partitions?()A Allocate the HBA to a client partition.B Restart the Virtual I/O Server to detect the changes.C Install the device driver for the DS8000 in each of the four AIX partitions.D Allocate the HBA to the VIO server partition and install necessary drivers.

问题 单选题Company.com has a VIO server with a configured virtual Ethernet adapter and a physical Ethernet adapter with an IP address on their local public network. They want to re-configure the physical Ethernet adapter as Shared Ethernet Adapter. When the mkvdev command is run, the following method error is returned: /usr/lib/methods/cfgsea . Which of the following will most likely resolve the problem?()A Run cfgdev on the VIO server and re-run the mkvdev command.B Run chdev -a sea_enable=yes on the physical Ethernet adapter.C Remove and re-add the virtual Ethernet adapter.D Remove the IP address from the physical adapter and re-run the mkvdev command.

问题 单选题Which of the following steps should be done FIRST when deploying a Virtual I/O server on a p5-550, which will host three logical partitions: a NIM server and two application servers?()A Create and install the NIM serverB Create and install the Virtual I/O ServerC Create and install the application serversD Activate Advanced POWER Virtualization

问题 单选题A resource was dynamically assigned to an LPAR. The customer wants to make the assignment permanent.  What does the technical specialist need to do to reconfigure the LPARs to make the assignment permanent?()A Reboot the source LPAR.B Remove the resource from the source LPAR.C Rediscover the managed system from the HMC.D Add the resource to the profile of the LPAR.

问题 单选题A client partition has the rootvg disks mapped from two separate VIO servers. They are using AIX mirroring to provide redundancy on rootvg. One of the VIO servers was taken down for maintenance and is now back on-line. The client partitions now show Physical Partition Marked Stale in the errpt. Which of the following will most likely resolve the problem?()A Run cfgmgr to re-scan the devices.B Run mkvdev on the VIO server to re-create the devices and re-mirror rootvg.C Run varyonvg rootvg to refresh the volume group.D Run syncvg on the rootvg to synchronize rootvg.

问题 单选题Company.com has four pSeries servers in their data center and wants to deploy multiple Micro-Partitions.  Which of the following data center servers can be used for this purpose?()A p5-520 running Virtual I/O ServerB p690 running AIX 5L V5.3C p5-510 running AIX 5L V5.2D p5-520 running two dedicated processor partitions

问题 单选题ompany.com has a Micro-Partitioned p5-570 4-way with six application partitions and two VIO servers. Each VIO server has been allocated 0.5 CPU and the application servers have been allocated 0.4 CPUs. The marketing department wants to deploy a new Web server to support the release of a product. The systems architect has recommended that the Web server will require a whole CPU. Which of the following should the technical specialist suggest to provide the most cost-effective deployment?()A Remove one application server partition and apply its CPU resources to the Web server.B Reassign the CPU from one of the VIO servers and create the new partition.C Add 0.6 CPU to one of the application servers and run the Web service with the application. D Reassign a total of 0.4 CPUs from the application servers and create a new partition with awhole CPU for new deployment.

问题 单选题A technical specialist has a requirement to implement a 4-way POWER5 server with a small Web server partition and a high performance database server partition. The Web server provides a client front-end to the database server. The most important concerns are speed of communication between the Web server and the database and I/O speed of the database. Which of the following virtualization features would be most appropriate?()A Virtual SCSIB Virtual EthernetC Virtual I/O ServerD Micro-Partitioning

问题 单选题Which of the following allows the user to have two separate Ethernet networks share the same network adapter?()A VLAN tagsB EtherChannelC Virtual EthernetD Shared Ethernet Adapter

问题 单选题Company.com wants to reassign a host bus adapter (HBA) from one partition to another to  handle increased I/O workload on that partition. What needs to be done to dynamically move the card?()A Use the rmdev command to remove the card from the current partition before doing the DLPAR process.B Take the source partition down and do the DLPAR function on the target partition.C Assign the card to the required section of the target partition and run cfgmgr.D Dynamically remove the card from the source and add to target profile then reactivate the target profile.

问题 单选题After rebuilding the list of virtual devices used by the VIO server using the "cfgdev" command, which command would be run to verify that a newly configured virtual SCSI adapter is available?()A lsdev -virtualB lsdev -Cs scsiC lscfg -vlD lsdev -adapter

问题 单选题Company.com has recently received a new p5-570 in the data center and wants to Micro-Partition the server. The customer already has an existing HMC connected to a p690. Which of the following actions should the technical specialist take?()A Order a POWER5 HMCB Connect to the existing HMCC Install an 8-port asynchronous card in the managed server to connect to the existing HMCD Install an additional network card to the existing HMC and connect to the POWER5 service processor

问题 单选题Which commands can the technical specialist use in AIX 5.3 to display the Hypervisor and virtual processor affinity statistics?()A lpstat and mpstatB lparstat and mpstatC lpstat and vmstatD vmstat and sar